C ProX Series Inverters 1.5 kW to 8 kW
The C ProX Series is a flexible MPPT inverter platform for standalone residential, agricultural, and light-commercial systems. Four power levels cover compact 12 V battery installations through to higher-capacity 48 V systems. Pure sine-wave output, grid and generator input support, BMS communication, and integrated Wi-Fi provide a controlled foundation for modern off-grid power systems.
The 1.5K and 4.2K models start their MPPT range at 30 V DC, supporting lower-voltage PV arrangements. The 6.2K and 8K models operate from 90 V DC, with battery-independent operation requiring at least 100 V DC on the 6.2K according to the official technical sheet. Maximum PV capacity ranges from 2000 W on the 1.5K to 10000 W across two PV inputs on the 8K.
The 4.2K, 6.2K, and 8K models provide dual AC outputs. This allows priority loads and optional loads to be separated so that essential equipment can be managed independently when battery state or available generation is limited. Charging-current capability of up to 120 A supports appropriately engineered battery banks and higher daily energy throughput.
Model selection must consider more than nominal wattage. Battery voltage, PV input current, number of PV inputs, battery-only output capability, motor-starting demand, and required separation between essential and non-essential loads all influence the correct configuration.
Key Features
- Four power levels from 1.5 kW to 8 kW
- Pure sine-wave single-phase output
- MPPT solar charging
- Battery-independent operation option
- Dual AC outputs on 4.2K, 6.2K, and 8K
- Integrated Wi-Fi remote monitoring
- RS485 BMS communication
- Grid and generator support
- Maximum charging current up to 120 A
- Wide PV input range and high surge capacity
Recommended Applications
- Standalone houses and rural residential projects
- Farms, workshops, barns, and agricultural facilities
- Small offices, shops, and service buildings
- Priority-load systems for refrigeration, communications, and security
- Generator-assisted solar and battery systems
- Lithium-battery projects requiring BMS communication
- Systems requiring essential/non-essential load separation
- Higher-load remote facilities using 48 V battery banks
Engineering and Selection Notes
- Use the battery-only output figure, not only rated power, when the system must support loads during periods without PV contribution.
- Dual-output models allow priority-load design, but the load allocation and control logic must be defined during system engineering.
- Verify PV operating voltage, cold-weather open-circuit voltage, and per-input current against the selected model.
- The 8K model provides two PV input paths and must be stringed according to the stated 22 A x 2 current limit and 5000 W x 2 power allocation.