A2Z EXIMCO Exporter & Supplier
A2Z EXIMCOExporter & Supplier
Home Page
ProductsBlog

Navigation

A2Z Group
Home Page
Products
Blog

Departments

A2Z Agriculture
A2Z Construction
A2Z Energy
A2Z Renewable Energy
A2Z Safety

Language

Support

safety@a2zeximco.com+905530021952
Catalog
Electrical Safety Equipment
Electrical Insulating Gloves
Electrical Insulating Gloves
REF: E8BE14

Electrical Insulating Gloves

LINEPRO Electrical Insulating Gloves are designed for professional electrical safety applications where reliable hand protection against electrical hazards is required. Manufactured from specially processed natural rubber latex compounds, each glove is tested and approved for electrical insulation performance.

 

The gloves are supplied in protective UV-resistant opaque bags and individual packaging to help preserve product integrity during storage and transportation. Their anatomical structure and flexibility at low temperatures support user comfort during long working periods.

 

LINEPRO insulating gloves are suitable for use in energy applications, power plants, high-voltage equipment maintenance, telecommunications and transportation industries. The product range covers Class 00 to Class 4, offering protection levels from low-voltage applications up to high-voltage electrical environments.

Key Features

  • Made from natural rubber
  • Designed for electrical insulation protection
  • Suitable for low-voltage and high-voltage applications
  • Available from Class 00 to Class 4
  • Tested according to EN 60903:2003 and IEC 60903:2014
  • CAT III PPE category
  • Anatomical design for improved user comfort
  • Flexible structure for use in low-temperature conditions
  • Supplied in protective packaging for safer storage
  • Suitable for energy, utility, telecom and electrical maintenance operations 

Technical Specifications

SpecificationDetails
Product TypeElectrical Insulating Gloves
MaterialNatural Rubber
Cuff TypeStraight Bell Cuff
ColorRed
Size10/XL
Packaging1 Pair
Box Quantity12 Pairs
PPE CategoryCAT III
StandardsEN 60903:2003 / IEC 60903:2014
Additional StandardEN ISO 21420:2020

Resistance code meanings:
A: Acid resistance
H: Oil resistance
Z: Ozone resistance
M: High mechanical resistance
R: Acid, oil, ozone and high mechanical resistance
C: Extreme low temperature resistance

Electrical Test Values

ClassMaximum Use VoltageAC Proof Test VoltageAC Withstand Test Voltage
Class 00500 V AC / 750 V DC2.5 kV5 kV
Class 01,000 V AC / 1,500 V DC5 kV10 kV
Class 17,500 V AC / 11,250 V DC10 kV20 kV
Class 217,000 V AC / 25,500 V DC20 kV30 kV
Class 326,500 V AC / 39,750 V DC30 kV40 kV
Class 436,000 V AC / 54,000 V DC40 kV50 kV

The class selection must always be made according to the working voltage, risk assessment and applicable electrical safety procedures.

Order & Packaging Information

ModelSizeBarcodeCarton QuantityCarton DimensionsCarton Weight
Class 0010/XL868090793959112 Pairs39 × 42 × 45 cm6.4 kg
Class 010/XL868090793961412 Pairs39 × 42 × 45 cm6.4 kg
Class 110/XL868090793960712 Pairs39 × 42 × 45 cm6.4 kg
Class 210/XL868090793962112 Pairs39 × 42 × 45 cm6.4 kg
Class 310/XL868090793963812 Pairs39 × 42 × 45 cm6.4 kg
Class 410/XL868090793983612 Pairs39 × 42 × 45 cm6.4 kg

 

Application Areas

LINEPRO Electrical Insulating Gloves are suitable for:

  • Energy applications
  • Electrical power plants
  • High-voltage equipment maintenance and repair
  • Electrical infrastructure works
  • Telecommunications industry
  • Transportation industry
  • Utility and maintenance operations
  • Electrical panel, substation and grid-related work

The datasheet specifically lists energy applications, energy facilities, high-voltage equipment maintenance and repair, telecommunications and transportation industries as usage areas.

Storage, Maintenance & Retesting Notes

The gloves should not be folded, wrinkled, stretched or stored inside out. They should be cleaned with mild soap, rinsed with clean water and dried away from direct sunlight or heat sources. Contact with petroleum-based products, oils, grease, gasoline, hydraulic fluids, organic solvents, hand creams or pastes should be avoided.

The gloves should be stored in their protective bag when not in use. Storage areas should be away from heat sources, chemicals, oils, solvents, hazardous vapors, smoke, electrical discharge, direct sunlight, moisture and ozone sources. The storage temperature should not exceed 40°C.

According to the datasheet, gloves can be used within 12 months from production without retesting if they have not been put into use. Once they are put into use, they should be retested every six months.

 

Important:
Electrical insulating gloves must be selected according to the working voltage, risk category and applicable local safety regulations. For professional electrical operations, users should always follow authorized safety procedures and periodic inspection requirements.

A2Z EXIMCO Exporter & Supplier
A2Z EXIMCOExporter & Supplier

A2ZEXIMCO is a Türkiye-based export and sourcing company built on 25 years of sector experience through its manufacturing network and industry partnerships.

Navigation

  • Home Page
  • Catalog

Contact

  • Emailsafety@a2zeximco.com
  • Phone+905530021952
  • AddressAnkara/Türkiye

Operations

Global Supply Live

Our logistics network spans 4 continents with factory-direct sourcing capabilities.

WhatsApp
WarrantyGuaranteed
Spare PartsReliable
Support24/7 Live
Parameter SpecsApplication CategoryModel NodeLength OptionsModel NodeMaximum Use Voltage ACModel NodeMaximum Use Voltage DCModel NodeResistance CodesModel Node
Class 00Low Voltage28 cm / 36 cm500 V AC750 V DCA, C, Z
Class 0Low Voltage28 cm / 36 cm / 41 cm / 46 cm1,000 V AC1,500 V DCA, C, Z
Class 1High Voltage36 cm / 41 cm / 46 cm7,500 V AC11,250 V DCR, C
Class 2High Voltage36 cm / 41 cm / 46 cm17,000 V AC25,500 V DCR, C
Class 3High Voltage36 cm / 41 cm / 46 cm26,500 V AC39,750 V DCR, C
Class 4High Voltage36 cm / 41 cm / 46 cm36,000 V AC54,000 V DCR, C

Related Models